O. Lossy Transmission Line

Symbol Name: LTLINE

Syntax:

Oxxx L+ L- R+ R- <model>|<string expression>

Example:

O1 in 0 out 0 MyLossyTline
.model MyLossyTline LTRA(len=1 R=10 L=1u C=10n)

This is a single-conductor lossy transmission line. N1 and N2 are the nodes at port 1. N3 and N4 are the nodes at port 2. A model card is required to define the electrical characteristics of this circuit element.

Model parameters for Lossy Transmission Lines

Name Description Units/Type Default
R Resistance per unit length Ω 0.
L Inductance per unit length H 0.
G Conductivity per unit length 1/Ω 0.
C Capacitance per unit length F 0.
Len Number of unit lengths - 0.
Rel Relative rate of change of derivative to set a breakpoint 1.
Abs Absolute rate of change of derivative to set a breakpoint 1.
NoStepLimit Don't limit time- step to less than line delay (flag) not set
NoControl Don't attempt complex time-step control (flag) not set
LinInterp Use linear interpolation (flag) not set
MixedInterp Use linear interpolation when quadratic seems to fail (flag) not set
CompactRel Reltol for history compaction RELTOL
CompactAbs Abstol for history compaction ABSTOL
TruncNr Use Newton-Raphson method for time-step control (flag) not set
TruncDontCut Don't limit time-step to keep impulse-response errors low (flag) not set